Performance analysis for an inclined tubular still desalination integrated with evacuated tube collector
Faculty
Engineering
Year:
2021
Type of Publication:
ZU Hosted
Pages:
361–372
Authors:
Mohammed Hassan Abdulaziz Jubran Jubran
Staff Zu Site
Abstract In Staff Site
Journal:
Solar energy Elsevier
Volume:
1
Keywords :
Performance analysis , , inclined tubular still desalination
Abstract:
Energy efficiency is one of the major challenges in water desalination systems. In the present study, a novel improvement for the Evacuated tube collector as a vapor generator was proposed. This improvement is achieved by decreasing the heat capacity using a film of feed water beside the absorber tube. The proposed system operated in continuous feedwater flow with backup. An inclined tubular still was used for vapor condensation. The inclination angle of the still and its diameter were investigated. The study was performed experimentally with a theoretical analysis of the thermal energy conversion. Water film thicknesses (WFT) of 2, 4, and 6 mm were examined. The 2 mm WFT achieved the optimum overall efficiency of 53%. The tested diameters of the tubular still were 80, 120, and 160 mm. The 160 mm diameter achieved the highest overall efficiency of 60.2%. Moreover, the 160 mm diameter condenser achieved the best vapor storage option. The tested inclination angles of the still were 80◦, 62◦, and 45◦. The 45◦ angle achieved the best overall efficiency of 48.1%. The cost of the distilled water reaches 0.01205 $/L per unit collector area.
Author Related Publications
Mohammed Hassan Abdulaziz Jubran Jubran, "A hybrid model of an artificial neural network with thermodynamic model for system diagnosis of electrical power plant gas turbine", Elsevier, 2018
More
Mohammed Hassan Abdulaziz Jubran Jubran, "Risk Assessment and Control for Main Hazards in Reverse Osmosis Desalination Plants", science publishing group, 2018
More
Department Related Publications
Sayed Ahmed ELsayed Sayed, "Results of experimental study of heat transfer intensification process for boiling of refrigerant mixture on tubes surfaces", لايوجد, 1900
More
Sayed Ahmed ELsayed Sayed, "Static and dynamic performance of pilot hydraulic relief valves", لايوجد, 1900
More
Sayed Ahmed ELsayed Sayed, "Flow through capillary tubes of different geometries and its effect on heat pump performance", لايوجد, 1900
More
Sayed Ahmed ELsayed Sayed, "Experimental investigation of the performance of a cross- Flow heat exchange with bundle of semi- circular tubes", لايوجد, 1900
More
Nabil Hassan Mostafa Hassan , "3D Numerical and Experimental Analysis of Turbulence Energy Spectrum in Swirl Jet", لايوجد, 1900
More
جامعة المنصورة
جامعة الاسكندرية
جامعة القاهرة
جامعة سوهاج
جامعة الفيوم
جامعة بنها
جامعة دمياط
جامعة بورسعيد
جامعة حلوان
جامعة السويس
شراقوة
جامعة المنيا
جامعة دمنهور
جامعة المنوفية
جامعة أسوان
جامعة جنوب الوادى
جامعة قناة السويس
جامعة عين شمس
جامعة أسيوط
جامعة كفر الشيخ
جامعة السادات
جامعة طنطا
جامعة بنى سويف