Abstract:
This study was carried out to assess the distribution of thermal neutrons emitted directly from the core of the ET-RR-I reactor in ordinary concrete, ilmenite concrete and ilmenite-limonite concrete shields. Measurements were carried out by using a direct beam and a cadmium filtered beam of reactor neutrons. The neutron dose distributions were measured using Li2B4O7: Mn thermoluminescent dosimeters. The data obtained show that ilmenite concrete is better for slow and thermal neutron attenuation than both ordinary and ilmenite-limonite concretes. Also it was concluded that thermal neutrons emitted directly from the reactor core are highly absorbed within the first few centimeters of each type of concrete. The thickness of ilmenite concrete required to attenuate the doses of neutrons to a certain value along the beam axis for a direct reactor beam estimated to be about 75 and 57\% of the shield thickness made from ordinary and ilmenite-limonite concretes, respectively. Empirical formulae were derived to calculate the neutron dose distributions in ordinary, ilmenite and ilmenite-limonite concrete shields both along and perpendicular to the beam axis for both the direct reactor neutrons and the reactor thermal neutrons. Copyright (C) 1996 Elsevier Science Ltd
   
  Online    
PDF  
       