| Journal: |
Fracture and Structural Integrity
Gruppo Italiano Frattura
|
Volume: |
|
| Abstract: |
Most research on the mode II fracture toughness of fiber-reinforced concrete (FRC) has intentionally avoided bridging fibers at pre-notch surfaces by using a through-thickness crack (TTC) that cuts the entire thickness, including fibers in this region. The objective of the present research is to accurately measure mode II fracture toughness (K IIC) using double-notched cube (DNC) specimens on steel fiber reinforced self-compacting concrete (SFRSCC). The effects of precrack-to-specimen width ratios (a/w), ie, a/w= 0.3, 0.4, and 0.5, and fiber volume fraction percentage (Vf%), ie, Vf%= 1% and 1.5% were investigated. A comparison between K IIC measured through specimens having the TTC concept, ie, the absence of fiber bridging on the surfaces of the pre-notch, and those with the presence of fiber bridging on the surfaces of the pre-notch, ie, the matrix crack (MC) concept. For greater clarity, the SCC specimens were cast without fibers with (MC/C) or without fiber bridging on the pre-crack surfaces to determine the unique effect of the presence of fiber bridging on the pre-crack surfaces on enhancing K IIC. The results showed that DNC specimens with MC consistently obtained the highest mode K IIC for all values of a/w, indicating the greatest resistance to crack growth. K IIC increased as the a/w ratio increased. MC/C method, ie, the presence of fibers behind the crack front only, showed more effectiveness on the K IIC than the TTC, ie, the presence of fibers ahead of the crack front only. In general, the MC is an accurate method for measuring K IIC of FRC.
|
|
|