Zagazig University Digital Repository
Home
Thesis & Publications
All Contents
Publications
Thesis
Graduation Projects
Research Area
Research Area Reports
Search by Research Area
Universities Thesis
ACADEMIC Links
ACADEMIC RESEARCH
Zagazig University Authors
Africa Research Statistics
Google Scholar
Research Gate
Researcher ID
CrossRef
Diagnostic validity and reliability of BT-RADS in the management of recurrent high-grade glioma
Faculty
Medicine
Year:
2024
Type of Publication:
ZU Hosted
Pages:
Authors:
Staff Zu Site
Abstract In Staff Site
Journal:
Journal of Neuroradiology Elsevier
Volume:
Keywords :
Diagnostic validity , reliability , BT-RADS , , management , recurrent
Abstract:
Background and purpose BT-RADS is a new framework system for reporting the treatment response of brain tumors. The aim of the study was to assess the diagnostic performance and reliability of the BT-RADS in predicting the recurrence of high-grade glioma (HGG). Materials and Methods This prospective single-center study recruited 81 cases with previously operated and pathologically proven HGG. The patients underwent baseline and follow-up contrast-enhanced MRI (CE-MRI). Two neuro-radiologists with ten years-experience in neuroimaging independently analyzed and interpreted the MRI images and assigned a BT-RADS category for each case. To assess the diagnostic accuracy of the BT-RADS for detecting recurrent HGG, the reference standard was the histopathology for BT-RADS categories 3 and 4, while neurological clinical examination and clinical follow up were used as a reference for BT-RADS categories 1 and 2. The inter-reader agreement was assessed using the Cohen's Kappa test. Results The study included 81 cases of HGG, of which 42 were recurrent and 39 were non-recurrent HGG cases based on the reference test. BT-RADS 3B was the best cutoff for predicting recurrent HGG with a sensitivity of 90.5 % to 92.9 %, specificity of 76.9 % to 84.6 %, and accuracy of 83.9 % to 88.9 %, based on both readers. The BT-RADS showed a substantial inter-reader agreement with a K of 0.710 (P = 0.001). Conclusions The BT-RADS is a valid and reliable framework for predicting recurrent HGG. Moreover, BT-RADS can help neuro-oncologists make clinical decisions that can potentially improve the patient's outcome.
Author Related Publications
Department Related Publications
Mohamed Fathy Ahmed Gouda, "تقييم تغلغل سرطان بطانه الرحم للعضلات الرحميه باستخدام الكفاءات التشخيصيه بالموجات فوق الصوتيه بالمجس المهبلى وبالفحص بالرنين المغناطيسي وايضا بواسطة الكشاف الرحمى وذلك قبل اجراء الجراحة ", لايوجد, 1900
More
Ghada Kamal Abdelrazek Gohar, "مقارنه الفحص بذالرنين المغناطيسي بعد حقن المحلول في التجويف الرحمى مع التخطيط بالموجات فوق الصوتيه المائيه في تقييم امراض البطانه الرحميه وماتحتها", لايوجد, 1900
More
Ghada Kamal Abdelrazek Gohar, "مظاهر الحويصلات الجلدانيه والبشرانية داخل الجمجمة في التصوير بالرنين المغناطيسي", مجله الجمعيه المصريه للاشعه والطب النووى, 2006
More
Khaled Ahmed Mohamed Lakoz, "الموجات فوق الصوتيه والموجات فوق الصوتيه بالدوبلر الملون ومولد المضاد السرطانى 125- في مصل الدم للتفريق بين اورام المبيض الحميدة والخبيثه", المجله المصريه للاشعه والطب النووى, 1997
More
Khaled Ahmed Mohamed Lakoz, "تقييم الاشعه المقطعيه بالحاسب الالى مع صبغه الجيوب المخيه في حالات الارتشاح الانفى للسائل النخاعى الشوكى", المجله المصريه للاشعه والطب النووى, 1998
More
جامعة المنصورة
جامعة الاسكندرية
جامعة القاهرة
جامعة سوهاج
جامعة الفيوم
جامعة بنها
جامعة دمياط
جامعة بورسعيد
جامعة حلوان
جامعة السويس
شراقوة
جامعة المنيا
جامعة دمنهور
جامعة المنوفية
جامعة أسوان
جامعة جنوب الوادى
جامعة قناة السويس
جامعة عين شمس
جامعة أسيوط
جامعة كفر الشيخ
جامعة السادات
جامعة طنطا
جامعة بنى سويف