Seismic retrofitting of a deteriorated RC building
Faculty
Engineering
Year:
2022
Type of Publication:
ZU Hosted
Pages:
18 (2023) e01758
Authors:
Mohammed Ahmed Sleim Mohamadien
Staff Zu Site
Abstract In Staff Site
Journal:
Case Studies in Construction Materials ElSevier
Volume:
e01758
Keywords :
Seismic retrofitting , , deteriorated , building
Abstract:
Numerous existing reinforced concrete (RC) buildings don’t fulfill current seismic code provisions as they haven’t been designed to satisfy these provisions. Also, due to many environmental factors, structural members such as columns, beams, and slabs are exposed to severe deterioration leading to high-risk levels. In this research, the performance of an existing seven-floor reinforced concrete building in Zagazig city, Egypt, constructed about 50 years ago, without considering the seismic requirements prescribed in the current Egyptian code (ECP-2012) is studied. The studied building suffers severe deterioration in its main structural elements, especially the basement floor slab. SAP2000 software is utilized to evaluate the structural behavior of the building under vertical loads (dead and live loads). The model failed to fulfill the ECP-2012 requirements under the applied loads. After building investigation, a retrofitting technique was proposed through providing the building with new grid beams at the basement floor level as well as replacing the existing basement floor slab with a new one. Moreover, RC jackets were provided to all basement floor columns. Through response spectrum analysis (RSA), the performance of the building with the newly proposed technique was assessed considering a peak ground acceleration equals 0.15 g (seismic zone 3). The model showed a significant enhancement in its response that fulfilled the ECP requirements concerning both strength and serviceability. Utilizing SeismoStruct software, the horizontal capacity of the model was inspected through the pushover analysis to check the efficiency of the proposed retrofitting technique. The model showed acceptable capacity in its two main directions.
Author Related Publications
Mohammed Ahmed Sleim Mohamadien , "Performance Evaluation of Outrigger System in Tall Buildings", www.ijtrd.com, 2017
More
Mohammed Ahmed Sleim Mohamadien , "A Parametric study of buildings with outrigger system provided by viscous dampers", www.ijtrd.com, 2017
More
Mohammed Ahmed Sleim Mohamadien , "Effect of pre-tensioning force on behavior of Buckling Restrained Brace (BRB) supported by double pre-tensioning system", Gruppo Italiano Frattura, 2024
More
Mohammed Ahmed Sleim Mohamadien , "Structural efficiency of fly-ash based concrete beam-column joint reinforced by hybrid GFRP and steel bars", ElSevier, 2025
More
Mohammed Ahmed Sleim Mohamadien , "Performance of GFRP-Confined Rubberized Engineered Cementitious Composite Columns", MDPI, 2024
More
Department Related Publications
Elsayed saad Abdelsalam Salman, "S. Abdel Salam, A. Akl, O. Shallan, “DYNAMIC ANALYSIS OF TUNNEL”, Proceedings of the International Congress on Tunneling and ground Conditions, 3-7 April 1994, national Authority for Tunnels, Cairo, Egypt.", Proceedings of the International Congress on Tunneling and ground Conditions national Authority for Tunnels, Cairo, Egypt., 1994
More
Mohamed Salah Amin Abdelaal, "Ultrasonic characterization of expanded polystyrene used for shallow tunnels under seismic excitation", journal homepage: www.sciencedirect.com, 2022
More
Hanaa Alsayed Elsayed Abdelmoteleb, "Ultrasonic characterization of expanded polystyrene used for shallow tunnels under seismic excitation", journal homepage: www.sciencedirect.com, 2022
More
Sali Elsaid Abdelmageed Hassn, "Numerical analysis of underground tunnels subjected to surface blast loads", Frattura ed Integrità Strutturale, 2021
More
جامعة المنصورة
جامعة الاسكندرية
جامعة القاهرة
جامعة سوهاج
جامعة الفيوم
جامعة بنها
جامعة دمياط
جامعة بورسعيد
جامعة حلوان
جامعة السويس
شراقوة
جامعة المنيا
جامعة دمنهور
جامعة المنوفية
جامعة أسوان
جامعة جنوب الوادى
جامعة قناة السويس
جامعة عين شمس
جامعة أسيوط
جامعة كفر الشيخ
جامعة السادات
جامعة طنطا
جامعة بنى سويف