MRI-Based Classification for Tibial Spine Fracture: Detection Efficacy, Classification Accuracy, and Reliability

Faculty Medicine Year: 2023
Type of Publication: ZU Hosted Pages:
Authors:
Journal: Academic Radiology Elsevier Volume:
Keywords : MRI-Based Classification , Tibial Spine Fracture: Detection    
Abstract:
ationale and Objectives: Recently, a new MRI-based classification for evaluating tibial spine fractures (TSFs) was developed to aid in treating these injuries. Our objective was to assess the detection efficacy, classification accuracy, and reliability of this classification in detecting and grading TSFs, as well as its impact on treatment strategy, compared to the Meyers and McKeever (MM) classification. Materials and Methods: A retrospective study included 68 patients with arthroscopically confirmed TSFs. All patients had plain radiography and conventional MRI of the affected knee before arthroscopy. Three experienced radiologists independently reviewed all plain radiographs and MRI data and graded each patient according to MM and MRI-based classifications. The detection efficacy, classification accuracy, and inter-rater agreement of both classifications were evaluated and compared, using arthroscopic findings as the gold standard. Results: The final analysis included 68 affected knees. Compared to the MM classification, the MRI-based classification produced 22.0% upgrade of TSFs and 11.8% downgrade of TSFs. According to the reviewers, the fracture classification accuracy of the MRIbased classification (91.2–95.6%) was significantly higher than that of the MM classification (73.5–76.5%, p = 0.002–0.01). The fracture detection rate of MRI-based classification (94.1–98.5%) was non-significantly higher than that of the MM classification (83.8–89.7%, p = 0.07–0.4). The soft tissue injury detection accuracy for MRI-based classification was 91.2–94.1%. The inter-rater reliability for grading TSFs was substantial for both the MM classification (κ = 0.69) and MRI-based classification (κ = 0.79). Conclusion: MRI-based classification demonstrates greater accuracy and reliability compared to MM classification for detecting and grading TSFs and associated soft tissue injuries
   
     
 
       

Author Related Publications

  • Rania Mostafa Mohammed El Molla, "Magnetic resonance imaging and 3-dimensional transperineal ultrasound evaluation of pelvic floor dysfunction in symptomatic women: a prospective comparative study", Korean Society of Ultrasound in Medicine (KSUM), 2019 More
  • Rania Mostafa Mohammed El Molla, "Supersonic shear waves quantitative elastography and kinetic magnetic resonance dynamic curve in discriminating BI-RADS 4 breast masses: A comparative study", elsevier, 2106 More
  • Rania Mostafa Mohammed El Molla, "Radiological middle turbinate variations and their relation to nasal septum deviation in asymptomatic adult", elsevier, 2018 More
  • Rania Mostafa Mohammed El Molla, "Quantitative scintigraphy using sacroiliac index in differentiating between normal and abnormal radioactive uptake of the sacroiliac joint", elsevier, 2018 More
  • Rania Mostafa Mohammed El Molla, "Is FDG maximum standardized uptake value of primary breast cancer a prognostic factor for locoregional axillary lymph node metastasis?", SAGE journals, 2018 More

Department Related Publications

  • Mohamed Fathy Ahmed Gouda, "تقييم تغلغل سرطان بطانه الرحم للعضلات الرحميه باستخدام الكفاءات التشخيصيه بالموجات فوق الصوتيه بالمجس المهبلى وبالفحص بالرنين المغناطيسي وايضا بواسطة الكشاف الرحمى وذلك قبل اجراء الجراحة ", لايوجد, 1900 More
  • Ghada Kamal Abdelrazek Gohar, "مقارنه الفحص بذالرنين المغناطيسي بعد حقن المحلول في التجويف الرحمى مع التخطيط بالموجات فوق الصوتيه المائيه في تقييم امراض البطانه الرحميه وماتحتها", لايوجد, 1900 More
  • Ghada Kamal Abdelrazek Gohar, "مظاهر الحويصلات الجلدانيه والبشرانية داخل الجمجمة في التصوير بالرنين المغناطيسي", مجله الجمعيه المصريه للاشعه والطب النووى, 2006 More
  • Khaled Ahmed Mohamed Lakoz, "الموجات فوق الصوتيه والموجات فوق الصوتيه بالدوبلر الملون ومولد المضاد السرطانى 125- في مصل الدم للتفريق بين اورام المبيض الحميدة والخبيثه", المجله المصريه للاشعه والطب النووى, 1997 More
  • Khaled Ahmed Mohamed Lakoz, "تقييم الاشعه المقطعيه بالحاسب الالى مع صبغه الجيوب المخيه في حالات الارتشاح الانفى للسائل النخاعى الشوكى", المجله المصريه للاشعه والطب النووى, 1998 More
Tweet