Cardiac device-related infective endocarditis need for lead extraction whatever the device according to the ESC EORP EURO-ENDO registry

Faculty Medicine Year: 2023
Type of Publication: ZU Hosted Pages:
Authors:
Journal: European Heart Journal Open Oxford University Press Volume: 4
Keywords : Cardiac device-related infective endocarditis need , lead    
Abstract:
Abstract Aims Cardiac device–related infective endocarditis (CDRIE) is a severe complication of cardiac device (CD) implantation and is usually treated by antibiotic therapy and percutaneous device extraction. Few studies report the management and prognosis of CDRIE in real life. In particular, the rate of device extraction in clinical practice and the management of patients with left heart infective endocarditis (LHIE) and an apparently non-infected CD (LHIE+CDRIE−) are not well described. Methods and results We sought to study in EURO-ENDO, the characteristics, prognosis, and management of 483 patients with a CD included in the European Society of Cardiology EurObservational Research Programme EURO-ENDO registry. Three populations were compared: 280 isolated CDRIE (66.7 ± 14.3 years), 157 patients with LHIE and an apparently non-infected CD (LHIE+CDRIE−) (71.1 ± 13.6), and 46 patients with both LHIE and CDRIE (LHIE+CDRIE+) (70.2 ± 10.1). Echocardiography was not always transoesophageal echography (TOE); it was transthoracic echography (TTE) for isolated CDRIE in 88.4% (TOE = 67.6%), for LHIE+CDRIE− TTE = 93.0% (TOE = 58.6%), and for CDRIE+LHIE+ TTE = 87.0% (TOE = 63.0%). Nuclear imaging was performed in 135 patients (positive for 75.6%). In-hospital mortality was lower in isolated CDRIE 13.2% vs. 22.3% and 30.4% for LHIE+CDRIE− and LHIE+CDRIE+ (P = 0004). Device extraction was performed in 62.1% patients with isolated CDRIE, 10.2% of LHIE+CDRIE− patients, and 45.7% of CDRIE+LHIE+ patients. Device extraction was associated with a better prognosis [hazard ratio 0.59 (0.40–0.87), P = 0.0068] even in the LHIE+CDRIE− group (P = 0.047). Conclusion Prognosis of endocarditis in patients with a CD remains poor, particularly in the presence of an associated LHIE. Although recommended by guidelines, device extraction is not always performed. Device removal was associated with better prognosis, even in the LHIE+CDRIE− group.
   
     
 
       

Author Related Publications

  • Aly Mohamed Abdelrahman Saad, "The prevalence of abnormal glucose regulation in patients with coronary artery disease across Europe The Euro Heart Survey on diabetes and the heart", Elsevier, 2004 More
  • Aly Mohamed Abdelrahman Saad, "Treatment and Health Status in Patients with Proven Coronary Artery Disease, but Ineligible for Revascularization. A Report from the Euro Heart Survey on Revascularization", Sage, 2006 More
  • Aly Mohamed Abdelrahman Saad, "Pharmacological treatment and perceived health status during 1-year follow up in patients diagnosed with coronary artery disease, but ineligible for revascularization: Results from the Euro Heart Survey on coronary revascularization", Sage, 2006 More
  • Aly Mohamed Abdelrahman Saad, "A 1-year follow up in patients diagnosed with coronary artery disease, but ineligible for revascularization. Results from The Euro Heart Survey on Coronary Revascularization", Oxford University Press, 2006 More
  • Aly Mohamed Abdelrahman Saad, "Atrial fibrillation management: a prospective survey in ESC Member Countries", Oxford University Press, 2005 More

Department Related Publications

  • Mohammed Ibrahim Amin Ibrahim Musa, "HbA1c And Insulin Resistance As Predictors For The Severity Of Coronary Artery Disease And Systolic Heart Failure In Non Diabetic Patients.", مجله كليه الطب البشري - جامغه الزقازيق, 2014 More
  • Muntasir Mustafa Ahmad, "قيمة الاجابة مضيق الشرايين التاجيين كمؤشر لضيق الشريان الكلوي", لايوجد, 1900 More
  • Muntasir Mustafa Ahmad, "قيمة سملة البطتنة والقيمة الوسطي للشرايين كعامل غير نافذ للتنبؤ بمرض الشريان التاجي", لايوجد, 1900 More
  • Muntasir Mustafa Ahmad, "المسافة بين نقطة التقاء وريقات الصمام الميترالي ومستواة الحلقي كمؤشر ", لايوجد, 1900 More
  • Muntasir Mustafa Ahmad, "قياس حركة ومسدحة الحلقة الشرفية الثلاثية كوسيلة لتنظيم وظيفة القلب ", لايوجد, 1900 More
Tweet