The utility of technetium-99m pertechnetate thyroid scintigraphy assessing thyroid/salivary ratio as an alternative to thyroid uptake percentage in evaluation of thyroid function, with establishing normal reference values of both parameters: single Egyptian center study

Faculty Medicine Year: 2022
Type of Publication: ZU Hosted Pages: 7
Authors:
Journal: Nuclear Medicine Communications Wolters Kluwer Health Volume:
Keywords : , utility , technetium-99m pertechnetate thyroid scintigraphy assessing    
Abstract:
The utility of technetium-99m pertechnetate thyroid scintigraphy assessing thyroid/salivary ratio as an alternative to thyroid uptake percentage in evaluation of thyroid function, with establishing normal reference values of both parameters: single Egyptian center study Heba M. Abdelhameda, Mohamed S. Abdo Solimanb, Amira A. Mahmoudc, Ramadan Mohamedd, Ismail M. Alie and Shaimaa F. Abdelhaia Background/Objective Management of thyroid disorders depends on accurate clinical assessment, appropriate investigations and radionuclide imaging, which plays an established important role either qualitatively or quantitatively. The aim of this study was to assess the utility of the thyroid/salivary ratio (TSR) as an alternative to technetium-99m (Tc99m) pertechnetate thyroid uptake (TcU) percentage in the evaluation of thyroid function and in the same time to establish reference range for the thyroid uptake of Tc99m-pertechnetate and TSR among Egyptian populations. Patients and methods This retrospective study enrolled 270 patients, out of which 250 with different thyroid disorders and 20 without thyroid diseases, as a control group who all underwent full clinical examination, thyroid function tests and Tc99m pertechnetate thyroid scintigraphy. The TcU percentage and TSR were calculated and then correlated to the thyroid hormonal profile. Results The normal reference ranges of TcU and TSR were 0.75–3.5% and 1.25–4.8%, respectively. The sensitivity and specificity of TSR to diagnose hyperthyroidism were slightly lower compared with TcU (84.5 and 92.3% vs. 86.2 and 98.3%, respectively) at TSR cutoff value of more than 4.8 and TcU cutoff value of more than 3.5. Meanwhile, they had comparable sensitivity and specificity to diagnose hypothyroidism (86.0 and 93.3% vs. 86.5 and 94.5%) at cutoff values <0.75 and <1.25, respectively. Conclusion The current study established a reference range for TcU and TSR in our institution. TSR is comparable to TcU in the evaluation of thyroid function among hyper-and hypothyroid patients and TSR can be used in doubtful cases of mal-thyroid function for confirmation of the diagnosis.
   
     
 
       

Author Related Publications

  • Ismail Mohamed Ali Hessien , "Long-term scintigraphic and clinical follow up in patients with differentiated thyroid cancer and iodine avid bone metastases", Wolters Kluwer Health, 2020 More
  • Ismail Mohamed Ali Hessien , "18F-FDG PET/CT in Therapy Response Assessment: Oligometastatic Colorectal", ٍSpringer, 2023 More
  • Ismail Mohamed Ali Hessien , "Outcome after surgery and radioactive 131- iodine ablation/treatment of Papillary Thyroid Carcinoma with Desmoplastic Reaction, Our Experience", Egyptian J. Nucl. Med, ekb, 2017 More
  • Ismail Mohamed Ali Hessien , "18FDG-PET/CT versus Contrast Enhanced CT in Detection of Loco-Regional Breast Cancer Recurrence.", Egyptian J. Nucl. Med, EKB, 2017 More
  • Ismail Mohamed Ali Hessien , "F-18 FDG PET-CT Versus Contrast Enhanced CT in Detection of Extra Nodal Involvement in Patients with Lymphoma", Wolters Kluwer ‑ Medknow, 2018 More

Department Related Publications

  • Mohammad Abd Alkhalik Basha, "Precision Mapping of Intrahepatic Biliary Anatomy and Its Anatomical Variants Having a Normal Liver Using 2D and 3D MRCP", MDPI, 2023 More
  • Engy Fathi Ahmed Tantawi, "Added Value of Shear Wave Elastography (SWE) for Evaluation of Patients with Plantar Fasciitis القيمة المضافة لإستخدام قياس مرونة الأنسجة باستخدام الموجات فوق الصوتية لتقييم حالات اللفافة الأخمصية", Zagazig University Medical Journal, 2023 More
  • Engy Fathi Ahmed Tantawi, "COVID-19 in Children: A Retrospective Comprehensive Analysis رؤى حول أنماط التصوير العصبي بالرنين المغناطيسي لكوفيد-19 في الأطفال: تحليل شامل استعادي", Academic Radiology, 2024 More
  • Mohamed Hamed Mohammed Abu Warda, "التفريق بين آفات البنكرياس باستخدام التصوير بالرنين المغناطيسي الأنتشارى", Egyptian Journal of Radiology and Nuclear Medicine (2015) 46, 563–568, 2015 More
  • Hossameldeen Mansour Abdelrahman Abdelrahman, "ROLE OF MULTISLICE CT AND MAGNETIC RESONANCE CHOLANGIOGRAPHY IN PREOPERATIVE EVALUATION OF POTENTIAL DONOR IN LIVING RELATED LIVER TRANSPLANTATION", مجلة الجمعية المصرية للأشعة والطب النووى, 2016 More
Tweet