CORONARY CT ANGIOGRAPHY WITH PHOTON-COUNTING CT: FIRST-IN-HUMAN RESULTS

Faculty Medicine Year: 2022
Type of Publication: ZU Hosted Pages:
Authors:
Journal: Radiology RADIOLOGICAL SOC NORTH AMERICA Volume:
Keywords : CORONARY , ANGIOGRAPHY WITH PHOTON-COUNTING , FIRST-IN-HUMAN RESULTS    
Abstract:
BACKGROUND: Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. PURPOSE: To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. MATERIALS AND METHODS: In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65–75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method. RESULTS: Fourteen consecutive participants (12 men; mean age, 61 years 6 17) were enrolled. Scores of overall quality and diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs 6 0 versus 349 mAs 6 111 for EID DLCT images (P , .01). Proportions of improvement with PCCT images for quality of calcification, stent, and noncalcified plaque were 100%, 92% (95% CI: 71, 98), and 45% (95% CI: 28, 63), respectively. In the phantom study, detectability indexes were 2.3-fold higher for lumen and 2.9-fold higher for noncalcified plaques with PCCT images. CONCLUSION: Coronary CT angiography with a photon-counting CT system demonstrated in humans an improved image quality and diagnostic confidence compared with an energy-integrating dual-layer CT.
   
     
 
       

Author Related Publications

  • Reham Amir Kamal Desouqy, "Magnetic Resonance Neurography of the Lumbosacral Plexus in Failed Back Surgery Syndrome", LIPPINCOTT WILLIAMS & WILKINS, TWO COMMERCE SQ, 2001 MARKET ST, PHILADELPHIA, PA 19103 USA, 2018 More
  • Reham Amir Kamal Desouqy, "A conventional-to-spectral CT image translation augmentation workflow for robust contrast injection-independent organ segmentation", WILEY, 2021 More
  • Reham Amir Kamal Desouqy, "Comparison of free breathing 3D mDIXON with single breath-hold 3D inversion recovery sequences for the assessment of Late Gadolinium Enhancement", ELSEVIER IRELAND LTDELSEVIER HOUSE, BROOKVALE PLAZA, EAST PARK SHANNON, CO, CLARE 00000, IRELAND, 2021 More
  • Reham Amir Kamal Desouqy, "FIRST IN-HUMAN RESULTS OF COMPUTED TOMOGRAPHY ANGIOGRAPHY FOR CORONARY STENT ASSESSMENT WITH A SPECTRAL PHOTON COUNTING COMPUTED TOMOGRAPHY", LIPPINCOTT WILLIAMS & WILKINS, 2022 More
  • Reham Amir Kamal Desouqy, "Feasibility of lung imaging with a large field-of-view spectral photon-counting CT system", ELSEVIER MASSON, CORP OFF, 65 CAMILLE DESMOULINS CS50083 ISSY-LES-MOULINEAUX, 92442 PARIS, FRANCE, 2021 More

Department Related Publications

  • Ghada Kamal Abdelrazek Gohar, "الفحص بالموجات فوق الصوتيه والدوبلر الملون في اعتلال الغدد الليمفاويه العنقيه", مجله جامعه الزقازيق الطبيه, 2005 More
  • Ghada Kamal Abdelrazek Gohar, "دور التصوير بالرنين المغناطيسي في حالات انتشار الاورام حول العصب الثلاثى التوائم", مجله الجمعيه المصرية للاشعه والطب النووى, 2006 More
  • Mohamed Alaa El Din Mohamed Tawfiq, "دور التصوير بالرنين المغناطيسي في حالات انتشار الاورام حول العصب الثلاثى التوائم", مجله الجمعيه المصرية للاشعه والطب النووى, 2006 More
  • Ghada Kamal Abdelrazek Gohar, "دور التصوير بالرنين المغناطيسي في حالات انتشار الاورام حول العصب الثلاثى التوائم", مجلة الجمعية المصرية للاشعة والطب النووى, 2003 More
  • Mohamed Alaa El Din Mohamed Tawfiq, "دور التصوير بالرنين المغناطيسي في حالات انتشار الاورام حول العصب الثلاثى التوائم", مجلة الجمعية المصرية للاشعة والطب النووى, 2003 More
Tweet