Zagazig University Digital Repository
Home
Thesis & Publications
All Contents
Publications
Thesis
Graduation Projects
Research Area
Research Area Reports
Search by Research Area
Universities Thesis
ACADEMIC Links
ACADEMIC RESEARCH
Zagazig University Authors
Africa Research Statistics
Google Scholar
Research Gate
Researcher ID
CrossRef
Validation of Coronary Artery Disease Reporting and Data System (CAD-RADS) and Application of Coronary Artery Calcium Data and Reporting System (CAC-DRS) as New Standardized Tools in the Management of Coronary Artery Disease Patients
Faculty
Medicine
Year:
2021
Type of Publication:
ZU Hosted
Pages:
Authors:
Staff Zu Site
Abstract In Staff Site
Journal:
nternational journal of general medicine International journal of general medicine
Volume:
Keywords :
Validation , Coronary Artery Disease Reporting , Data
Abstract:
Background and Objectives: The coronary artery disease reporting and data system (CAD-RADS) is intended to standardize the reporting of CCTA and the subsequent management guidelines of CAD. The present study was conducted to investigate the validation of CAD-RADS and the application of coronary calcium grading in CAD management. Patients and Methods: The current study is a single-center prospective study that involved 177 participants with chest pain who were submitted to coronary CT angiography (CCTA). Two reviewers independently assessed CCTA results and gave each patient a CAD-RADS category. The reference standard for determining the clinical utility of CAD-RADS was invasive coronary angiography (ICA). The inter-reviewer agreement (IRA) was tested using the intra-class correlation (ICC). Results: The study enrolled 111 cases with non-significant CAD and 66 cases with significant CAD based on ICA findings. According to the reviewer, the CAD-RADS had a sensitivity, specificity, and accuracy of 90.9 to 100%, 89.2 to 94.6%, and 93.16 to 93.2%, respectively, for predicting severe CAD. The IRA for CAD-RADS categories was excellent (ICC = 0.960). The best cut-off value for predicting severe CAD was CAD-RADS > 3. Significant relation between Ca and severe CAD (p< 0.001) was detected. Conclusion: The current study provides a good understanding of CAD-RADS as a standard tool with high diagnostic accuracy.
Author Related Publications
Department Related Publications
Mona Osman AbouElEzz, "CT and MRI in diagnosis of malignant tumors of pharynx and oral cavity", Zagazig University medical Journal, 2001
More
Ahmed Abdelaziz Elsayed Mohamd, "Diagnostic efficacy of the Liver Imaging-Reporting and Data System (LI-RADS) with CT imaging in categorising small nodules (10e20 mm) detected in the cirrhotic liver at screening ultrasound", science direct, 2017
More
Ahmad AbdelAzim esmaiyl, "THREE DIMENSIONAL MAGNETIC RESONANCE ANGIOGRAPHY OF THE CIRCLE OF WILLIS: ANATOMICAL VARIATIONS IN GENERAL EGYPTIAN POPULATION التصوير ثلاثي الأبعاد للأوعية الدموية لدائرة ويليس بالرنين المغناطيسي : الاختلافات التشريحية في الشعب المصري الع", الجمعية المصرية للأشعة والطب النووي, 2011
More
Faten Fawzy Mohamed Hafez, "THE ROLE OF APPARENT DIFFUSION COEFFICIENT (ADC) VALUE IN THE DIFFERENTIATION BETWEEN THE MOST COMMON PEDIATRIC POSTERIOR FOSSA TUMORS", فى مجلة الجمعة المصرية للأشعة والطب النووى, 2013
More
Faten Fawzy Mohamed Hafez, "DIAGNOSTIC VALUE OF APPARENT DIFFUSION COEFFICIENT (ADC) IN ASSESSMENT OF PITUITARY MACROADENOMA CONSISTENCY", فى مجلة الجمعة المصرية للأشعة والطب النووى, 2013
More
جامعة المنصورة
جامعة الاسكندرية
جامعة القاهرة
جامعة سوهاج
جامعة الفيوم
جامعة بنها
جامعة دمياط
جامعة بورسعيد
جامعة حلوان
جامعة السويس
شراقوة
جامعة المنيا
جامعة دمنهور
جامعة المنوفية
جامعة أسوان
جامعة جنوب الوادى
جامعة قناة السويس
جامعة عين شمس
جامعة أسيوط
جامعة كفر الشيخ
جامعة السادات
جامعة طنطا
جامعة بنى سويف