Role of MR Neurography for the Diagnosis of Peripheral Trigeminal Nerve Injuries in Patients with Prior Molar Tooth Extraction

Faculty Medicine Year: 2018
Type of Publication: ZU Hosted Pages:
Authors:
Journal: AMERICAN JOURNAL OF NEURORADIOLOGY AMER SOC NEURORADIOLOGY, PO BOX 3000, DENVILLE, NJ 07834-9349 USA Volume: 39
Keywords : Role , , Neurography , , Diagnosis , Peripheral Trigeminal Nerve    
Abstract:
:Abstract BACKGROUND AND PURPOSE: Clinical neurosensory testing is an imperfect reference standard to evaluate molar tooth extraction related peripheral trigeminal neuropathy. The purpose was to evaluate the diagnostic accuracy of MR neurography in this domain and correlation with neurosensory testing and surgery MATERIALS AND METHODS: In this retrospective study, nerve caliber, T2 signal intensity ratio, and contrast-to-noise ratios were recorded by 2 observers using MR neurography for bilateral branches of the peripheral trigeminal nerve, the inferior alveolar and lingual nerves. Patient demographics and correlation of the MR neurography findings with the Sunderland classification of nerve injury and intraoperative findings of surgical patients were obtained RESULTS: Among 42 patients, the mean +/- SD age for case and control patients were 35.8 +/- 10.2 years and 43.2 +/- 11.5 years, respectively, with male-to-female ratios of 1:1.4 and 1:5, respectively. Case subjects (peripheral trigeminal neuropathy or injury) had significantly larger differences in nerve thickness, T2 signal intensity ratio, and contrast-to-noise ratios than control patients for the inferior alveolar nerve and lingual nerve (P = .01 and .0001, .012 and .005, and .01 and .01, respectively). Receiver operating characteristic analysis showed a significant association among differences in nerve thickness, T2 signal intensity ratio, and contrast-to-noise ratios and nerve injury (area under the curve, 0.83-0.84 for the inferior alveolar nerve and 0.77-0.78 for the lingual nerve). Interobserver agreement was good for the inferior alveolar nerve (intraclass correlation coefficient, 0.70-0.79) and good to excellent for the lingual nerve (intraclass correlation coefficient, 0.75-0.85). MR neurography correlations with respect to clinical neurosensory testing and surgical classifications were moderate to good. Pearson correlation coefficients of kappa 0.68 and 0.81 and of 0.60 and 0.77 were observed for differences in nerve thickness CONCLUSIONS: MR neurography can be reliably used for the diagnosis of injuries to the peripheral trigeminal nerve related to molar tooth extractions, with good to excellent correlation of imaging with clinical findings and surgical results
   
     
 
       

Author Related Publications

  • Reham Amir Kamal Desouqy, "Magnetic Resonance Neurography of the Lumbosacral Plexus in Failed Back Surgery Syndrome", LIPPINCOTT WILLIAMS & WILKINS, TWO COMMERCE SQ, 2001 MARKET ST, PHILADELPHIA, PA 19103 USA, 2018 More
  • Reham Amir Kamal Desouqy, "A conventional-to-spectral CT image translation augmentation workflow for robust contrast injection-independent organ segmentation", WILEY, 2021 More
  • Reham Amir Kamal Desouqy, "Comparison of free breathing 3D mDIXON with single breath-hold 3D inversion recovery sequences for the assessment of Late Gadolinium Enhancement", ELSEVIER IRELAND LTDELSEVIER HOUSE, BROOKVALE PLAZA, EAST PARK SHANNON, CO, CLARE 00000, IRELAND, 2021 More
  • Reham Amir Kamal Desouqy, "FIRST IN-HUMAN RESULTS OF COMPUTED TOMOGRAPHY ANGIOGRAPHY FOR CORONARY STENT ASSESSMENT WITH A SPECTRAL PHOTON COUNTING COMPUTED TOMOGRAPHY", LIPPINCOTT WILLIAMS & WILKINS, 2022 More
  • Reham Amir Kamal Desouqy, "Feasibility of lung imaging with a large field-of-view spectral photon-counting CT system", ELSEVIER MASSON, CORP OFF, 65 CAMILLE DESMOULINS CS50083 ISSY-LES-MOULINEAUX, 92442 PARIS, FRANCE, 2021 More

Department Related Publications

  • Mohamed Fathy Ahmed Gouda, "تقييم تغلغل سرطان بطانه الرحم للعضلات الرحميه باستخدام الكفاءات التشخيصيه بالموجات فوق الصوتيه بالمجس المهبلى وبالفحص بالرنين المغناطيسي وايضا بواسطة الكشاف الرحمى وذلك قبل اجراء الجراحة ", لايوجد, 1900 More
  • Ghada Kamal Abdelrazek Gohar, "مقارنه الفحص بذالرنين المغناطيسي بعد حقن المحلول في التجويف الرحمى مع التخطيط بالموجات فوق الصوتيه المائيه في تقييم امراض البطانه الرحميه وماتحتها", لايوجد, 1900 More
  • Ghada Kamal Abdelrazek Gohar, "مظاهر الحويصلات الجلدانيه والبشرانية داخل الجمجمة في التصوير بالرنين المغناطيسي", مجله الجمعيه المصريه للاشعه والطب النووى, 2006 More
  • Khaled Ahmed Mohamed Lakoz, "الموجات فوق الصوتيه والموجات فوق الصوتيه بالدوبلر الملون ومولد المضاد السرطانى 125- في مصل الدم للتفريق بين اورام المبيض الحميدة والخبيثه", المجله المصريه للاشعه والطب النووى, 1997 More
  • Khaled Ahmed Mohamed Lakoz, "تقييم الاشعه المقطعيه بالحاسب الالى مع صبغه الجيوب المخيه في حالات الارتشاح الانفى للسائل النخاعى الشوكى", المجله المصريه للاشعه والطب النووى, 1998 More
Tweet