Head-to-head comparison of lung perfusion with dual-energy CT and SPECT-CT

Faculty Medicine Year: 2020
Type of Publication: ZU Hosted Pages: 299-310
Authors:
Journal: DIAGNOSTIC AND INTERVENTIONAL IMAGING ELSEVIER MASSON, CORP OFF, 65 CAMILLE DESMOULINS CS50083 ISSY-LES-MOULINEAUX, 92442 PARIS, FRANCE Volume: 101
Keywords : Head-to-head comparison , lung perfusion with dual-energy    
Abstract:
:Abstract Purpose: To compare the quantitative and qualitative lung perfusion data acquired with dual energy CT (DECT) to that acquired with a large field-of-view cadmium-zinc-telluride camera single-photon emission CT coupled to a CT system (SPECT-CT). Materials and methods: A total of 53 patients who underwent both dual-layer DECT angiography and perfusion SPECT-CT for pulmonary hypertension or pre-operative lobar resection surgery were retrospectively included. There were 30 men and 23 women with a mean age of 65.4 +/- 17.5 (SD) years (range: 18-88 years). Relative lobar perfusion was calculated by dividing the amount (of radiotracer or iodinated contrast agent) per lobe by the total amount in both lungs. Linear regression, Bland-Altman analysis, and Pearson's correlation coefficient were also calculated. Kappa test was used to test agreements in morphology and seventy of perfusion defects assessed on SPECT-CT and on DECT iodine maps with a one-month interval. Wilcoxon rank sum test was used to compare the sharpness of perfusion defects and radiation dose among modalities. Results: Strong correlations for relative lobar perfusion using linear regression analysis and Pearson's correlation coefficient (r = 0.93) were found. Bland-Altman analysis revealed a -0.10 bias, with limits of agreement between [-6.01; 5.81]. With respect to SPECT- CT as standard of reference, the sensitivity, specificity, PPV, NPV, accuracy for lobar perfusion defects were 89.4% (95% 'CI: 82.6-93.4%), 96.5% (95% CI: 92.1-98.5%), 95.6% (95% CI: '90.9-97.8%), 91.4% (95% CI: 85.6-94.9%) and 93.0% (95% CI: '87.6-96.1%) respectively. High level of agreement was found for morphology and severity of perfusion defects between modalities (Kappa =0.84 and 0.86 respectively) and on DECT images among readers (Kappa = 0.94 and 0.89 respectively). A significantly sharper delineation of perfusion defects was found on DECT images (P < 0.0001) using a significantly lower equivalent dose of 4.1 +/- 2.3 (SD) mSv (range: 1.9-11.85 mSv) compared to an equivalent dose of 5.3 +/- 1.1 (SD) mSv (range: 2.8-7.3 mSv) for SPECT-CT, corresponding to a 21.2% dose reduction (P = 0.0004). Conclusion: DECT imaging shows strong quantitative correlations and qualitative agreements with SPECT-CT for the evaluation of lung perfusion.
   
     
 
       

Author Related Publications

  • Reham Amir Kamal Desouqy, "Magnetic Resonance Neurography of the Lumbosacral Plexus in Failed Back Surgery Syndrome", LIPPINCOTT WILLIAMS & WILKINS, TWO COMMERCE SQ, 2001 MARKET ST, PHILADELPHIA, PA 19103 USA, 2018 More
  • Reham Amir Kamal Desouqy, "A conventional-to-spectral CT image translation augmentation workflow for robust contrast injection-independent organ segmentation", WILEY, 2021 More
  • Reham Amir Kamal Desouqy, "Comparison of free breathing 3D mDIXON with single breath-hold 3D inversion recovery sequences for the assessment of Late Gadolinium Enhancement", ELSEVIER IRELAND LTDELSEVIER HOUSE, BROOKVALE PLAZA, EAST PARK SHANNON, CO, CLARE 00000, IRELAND, 2021 More
  • Reham Amir Kamal Desouqy, "FIRST IN-HUMAN RESULTS OF COMPUTED TOMOGRAPHY ANGIOGRAPHY FOR CORONARY STENT ASSESSMENT WITH A SPECTRAL PHOTON COUNTING COMPUTED TOMOGRAPHY", LIPPINCOTT WILLIAMS & WILKINS, 2022 More
  • Reham Amir Kamal Desouqy, "Feasibility of lung imaging with a large field-of-view spectral photon-counting CT system", ELSEVIER MASSON, CORP OFF, 65 CAMILLE DESMOULINS CS50083 ISSY-LES-MOULINEAUX, 92442 PARIS, FRANCE, 2021 More

Department Related Publications

  • Ahmed Sabry Ahmed Ragheb, "Diagnostic value of apparent diffusion coefficient to differentiate benign from malignant vertebral bone marrow lesions", elsevier, 2013 More
  • Ahmed Sabry Ahmed Ragheb, "Can DWI & ADC differentiate orbital lymphoma, non-specific orbital inflammation and orbital cellulitis?", elsevier, 2014 More
  • Ahmed Sabry Ahmed Ragheb, "The outcome of partial splenic embolization for hypersplenism in the cirrhotic patients", elsevier, 2012 More
  • Ahmed Sabry Ahmed Ragheb, "Conventional endoscopy versus virtual laryngoscopy in assessment of laryngeal lesions", elsevier, 2013 More
  • Ahmed Sabry Ahmed Ragheb, "VOLUMETRIC MAGNETIC RESONANCE IMAGING CHANGES IN MILD COGNITIVE IMPAIRMENT AND ALZHEIMER’S DEMENTIA", elsevier, 2011 More
Tweet