Zagazig University Digital Repository
Home
Thesis & Publications
All Contents
Publications
Thesis
Graduation Projects
Research Area
Research Area Reports
Search by Research Area
Universities Thesis
ACADEMIC Links
ACADEMIC RESEARCH
Zagazig University Authors
Africa Research Statistics
Google Scholar
Research Gate
Researcher ID
CrossRef
Head-to-head comparison of lung perfusion with dual-energy CT and SPECT-CT
Faculty
Medicine
Year:
2020
Type of Publication:
ZU Hosted
Pages:
299-310
Authors:
Reham Amir Kamal Desouqy
Staff Zu Site
Abstract In Staff Site
Journal:
DIAGNOSTIC AND INTERVENTIONAL IMAGING ELSEVIER MASSON, CORP OFF, 65 CAMILLE DESMOULINS CS50083 ISSY-LES-MOULINEAUX, 92442 PARIS, FRANCE
Volume:
101
Keywords :
Head-to-head comparison , lung perfusion with dual-energy
Abstract:
:Abstract Purpose: To compare the quantitative and qualitative lung perfusion data acquired with dual energy CT (DECT) to that acquired with a large field-of-view cadmium-zinc-telluride camera single-photon emission CT coupled to a CT system (SPECT-CT). Materials and methods: A total of 53 patients who underwent both dual-layer DECT angiography and perfusion SPECT-CT for pulmonary hypertension or pre-operative lobar resection surgery were retrospectively included. There were 30 men and 23 women with a mean age of 65.4 +/- 17.5 (SD) years (range: 18-88 years). Relative lobar perfusion was calculated by dividing the amount (of radiotracer or iodinated contrast agent) per lobe by the total amount in both lungs. Linear regression, Bland-Altman analysis, and Pearson's correlation coefficient were also calculated. Kappa test was used to test agreements in morphology and seventy of perfusion defects assessed on SPECT-CT and on DECT iodine maps with a one-month interval. Wilcoxon rank sum test was used to compare the sharpness of perfusion defects and radiation dose among modalities. Results: Strong correlations for relative lobar perfusion using linear regression analysis and Pearson's correlation coefficient (r = 0.93) were found. Bland-Altman analysis revealed a -0.10 bias, with limits of agreement between [-6.01; 5.81]. With respect to SPECT- CT as standard of reference, the sensitivity, specificity, PPV, NPV, accuracy for lobar perfusion defects were 89.4% (95% 'CI: 82.6-93.4%), 96.5% (95% CI: 92.1-98.5%), 95.6% (95% CI: '90.9-97.8%), 91.4% (95% CI: 85.6-94.9%) and 93.0% (95% CI: '87.6-96.1%) respectively. High level of agreement was found for morphology and severity of perfusion defects between modalities (Kappa =0.84 and 0.86 respectively) and on DECT images among readers (Kappa = 0.94 and 0.89 respectively). A significantly sharper delineation of perfusion defects was found on DECT images (P < 0.0001) using a significantly lower equivalent dose of 4.1 +/- 2.3 (SD) mSv (range: 1.9-11.85 mSv) compared to an equivalent dose of 5.3 +/- 1.1 (SD) mSv (range: 2.8-7.3 mSv) for SPECT-CT, corresponding to a 21.2% dose reduction (P = 0.0004). Conclusion: DECT imaging shows strong quantitative correlations and qualitative agreements with SPECT-CT for the evaluation of lung perfusion.
Author Related Publications
Reham Amir Kamal Desouqy, "Magnetic Resonance Neurography of the Lumbosacral Plexus in Failed Back Surgery Syndrome", LIPPINCOTT WILLIAMS & WILKINS, TWO COMMERCE SQ, 2001 MARKET ST, PHILADELPHIA, PA 19103 USA, 2018
More
Reham Amir Kamal Desouqy, "A conventional-to-spectral CT image translation augmentation workflow for robust contrast injection-independent organ segmentation", WILEY, 2021
More
Reham Amir Kamal Desouqy, "Comparison of free breathing 3D mDIXON with single breath-hold 3D inversion recovery sequences for the assessment of Late Gadolinium Enhancement", ELSEVIER IRELAND LTDELSEVIER HOUSE, BROOKVALE PLAZA, EAST PARK SHANNON, CO, CLARE 00000, IRELAND, 2021
More
Reham Amir Kamal Desouqy, "FIRST IN-HUMAN RESULTS OF COMPUTED TOMOGRAPHY ANGIOGRAPHY FOR CORONARY STENT ASSESSMENT WITH A SPECTRAL PHOTON COUNTING COMPUTED TOMOGRAPHY", LIPPINCOTT WILLIAMS & WILKINS, 2022
More
Reham Amir Kamal Desouqy, "Feasibility of lung imaging with a large field-of-view spectral photon-counting CT system", ELSEVIER MASSON, CORP OFF, 65 CAMILLE DESMOULINS CS50083 ISSY-LES-MOULINEAUX, 92442 PARIS, FRANCE, 2021
More
Department Related Publications
Mohamed Fathy Ahmed Gouda, "تقييم تغلغل سرطان بطانه الرحم للعضلات الرحميه باستخدام الكفاءات التشخيصيه بالموجات فوق الصوتيه بالمجس المهبلى وبالفحص بالرنين المغناطيسي وايضا بواسطة الكشاف الرحمى وذلك قبل اجراء الجراحة ", لايوجد, 1900
More
Ghada Kamal Abdelrazek Gohar, "مقارنه الفحص بذالرنين المغناطيسي بعد حقن المحلول في التجويف الرحمى مع التخطيط بالموجات فوق الصوتيه المائيه في تقييم امراض البطانه الرحميه وماتحتها", لايوجد, 1900
More
Ghada Kamal Abdelrazek Gohar, "مظاهر الحويصلات الجلدانيه والبشرانية داخل الجمجمة في التصوير بالرنين المغناطيسي", مجله الجمعيه المصريه للاشعه والطب النووى, 2006
More
Khaled Ahmed Mohamed Lakoz, "الموجات فوق الصوتيه والموجات فوق الصوتيه بالدوبلر الملون ومولد المضاد السرطانى 125- في مصل الدم للتفريق بين اورام المبيض الحميدة والخبيثه", المجله المصريه للاشعه والطب النووى, 1997
More
Khaled Ahmed Mohamed Lakoz, "تقييم الاشعه المقطعيه بالحاسب الالى مع صبغه الجيوب المخيه في حالات الارتشاح الانفى للسائل النخاعى الشوكى", المجله المصريه للاشعه والطب النووى, 1998
More
جامعة المنصورة
جامعة الاسكندرية
جامعة القاهرة
جامعة سوهاج
جامعة الفيوم
جامعة بنها
جامعة دمياط
جامعة بورسعيد
جامعة حلوان
جامعة السويس
شراقوة
جامعة المنيا
جامعة دمنهور
جامعة المنوفية
جامعة أسوان
جامعة جنوب الوادى
جامعة قناة السويس
جامعة عين شمس
جامعة أسيوط
جامعة كفر الشيخ
جامعة السادات
جامعة طنطا
جامعة بنى سويف