Long-term follow-up of therapeutic efficacy of everolimus-eluting bioresorbable vascular scaffold in comparison to everolimus-eluting stent in treatment of chronic total occlusion guided by intracoronary imaging

Faculty Medicine Year: 2020
Type of Publication: ZU Hosted Pages: 1-13
Authors:
Journal: Egyptian Heart Journal SpringerOpen Volume:
Keywords : Long-term follow-up , therapeutic efficacy of everolimus-eluting bioresorbable vascular    
Abstract:
Background: We hypothesized that 1st generation everolimus-eluting bioresorbable vascular scaffold (BVS) stent associated with less complication and less restenosis rate than everolimus-eluting stent (EES) in chronic total occlusion (CTO) recanalization guided by intracoronary imaging. Therefore, we aimed to assess the safety and performance of BVS stent in CTO revascularization in comparison to EES guided by intracoronary imaging. Our prospective comparative cross-sectional study was conducted on 60 CTO patients divided into two groups according to type of stent revascularization: group I (EES group): 40 (66.7%) patients and group II (BVS group): 20 (33.3%) patients. All patients were subjected to history taking, electrocardiogram (ECG), echocardiography, laboratory investigation, stress thallium study to assess viability before revascularization. Revascularization of viable CTO lesion guided by intracoronary imaging using optical coherence tomography (OCT). Then, long-term follow-up over 1 year clinically and by multi-slice CT coronary angiography (MSCT). Our clinical and angiographic endpoints were to detect any clinical or angiographic complications during the follow-up period. Results: At 6 months angiographic follow-up, BVS group had not inferior angiographic parameters but without statistically significant difference (p = 0.566). At 12 months follow-up, there was no difference at end points between the two groups (p = 0.476). No differences were found at angiographic or clinical follow-up between BVS and EES. Conclusion: This study shows that 1st generation everolimus-eluting BVS is non-inferior to EES for CTO revascularization. Further studies are needed to clearly state which new smaller footprint BVS, faster reabsorption, magnesium-based less thrombogenicity, and advanced mechanical properties is under development. We cannot dismiss the efficacy and safety of new BVS technology. (Continued on next page)
   
     
 
       

Author Related Publications

  • Eslam Alsayed Mohamed Mohamed Shehata, "Resting Left Ventricular Systolic Dyssynchrony and Mechanical Reserve in Asymptomatic Normotensive Subjects with Early Type 2 Diabetes Mellitus", Karger, 2020 More
  • Eslam Alsayed Mohamed Mohamed Shehata, "Mitral annulus time intervals for assessment of left ventricular systolic function in ischemic cardiomyopathy", European Journal of Heart Failure Supplements (2012) 11, S128–S177, 2012 More
  • Eslam Alsayed Mohamed Mohamed Shehata, "Mitral annulus time intervals for assessment of left ventricular systolic function in dilated cardiomyopathy", European Journal of Heart Failure Supplements (2012) 11, S128–S177, 2012 More
  • Eslam Alsayed Mohamed Mohamed Shehata, "Comparison between drug-coated balloon angioplasty and second-generation drugeluting stent placement for the treatment of in-stent restenosis after drug-eluting stent implantation", Springer, 2016 More
  • Eslam Alsayed Mohamed Mohamed Shehata, "Coronary slow flow and its correlation with reduced left ventricle global longitudinal strain: a case–control study", Springer Nature, 2024 More

Department Related Publications

  • Mohammed Ibrahim Amin Ibrahim Musa, "HbA1c And Insulin Resistance As Predictors For The Severity Of Coronary Artery Disease And Systolic Heart Failure In Non Diabetic Patients.", مجله كليه الطب البشري - جامغه الزقازيق, 2014 More
  • Muntasir Mustafa Ahmad, "قيمة الاجابة مضيق الشرايين التاجيين كمؤشر لضيق الشريان الكلوي", لايوجد, 1900 More
  • Muntasir Mustafa Ahmad, "قيمة سملة البطتنة والقيمة الوسطي للشرايين كعامل غير نافذ للتنبؤ بمرض الشريان التاجي", لايوجد, 1900 More
  • Muntasir Mustafa Ahmad, "المسافة بين نقطة التقاء وريقات الصمام الميترالي ومستواة الحلقي كمؤشر ", لايوجد, 1900 More
  • Muntasir Mustafa Ahmad, "قياس حركة ومسدحة الحلقة الشرفية الثلاثية كوسيلة لتنظيم وظيفة القلب ", لايوجد, 1900 More
Tweet