Secondary Intraocular Lens Implantation After Simultaneous Penetrating Keratoplasty and Cataract Extraction for Coexisting Corneal and Lens Opacities

Faculty Medicine Year: 2019
Type of Publication: ZU Hosted Pages:
Authors:
Journal: Journal of Materials Science: Materials in Electronics Wolters Kluwer Volume:
Keywords : Secondary Intraocular Lens Implantation After Simultaneous Penetrating    
Abstract:
Purpose: To report the results of a new approach to the 2-stage surgical management of coexisting visually significant corneal opacities and cataract. Methods: A retrospective analysis of eyes with corneal opacities and cataract that were surgically treated with simultaneous penetrating keratoplasty and cataract surgery, followed by secondary intraocular lens (IOL) implantation after removal of corneal sutures, was conducted. The parameters used for assessment were the following: mean percentage of graft endothelial cell loss after IOL implantation, deviation of the postoperative mean spherical equivalent from the target refraction, and mean uncorrected distance visual acuity (UDVA). Results: Twenty-nine eyes were included in the study. The mean baseline UDVA was 1.94 6 0.46, and the mean baseline best-corrected distance visual acuity was 1.56 6 0.42. The mean interval between the 2 surgical interventions was 13.3 6 2.2 months. Just before secondary IOL implantation, the mean endothelial cell density was 2198 6 311 cells. The mean percentage of corneal endothelial cell loss was 7.3% at 6 months after IOL implantation (P = 0.16). Before IOL implantation, the mean spherical equivalent was +11.75 6 3.38 D. After IOL implantation, the mean spherical equivalent improved to 20.19 6 0.93 D (P = 0.003) at 6 months. The mean UDVA improved to 0.34 6 0.18 (P = 0.017), whereas the mean corrected distance visual acuity improved to 0.18 6 0.29 at 6 months (P = 0.016). All grafted corneas maintained their clarity until the final followup visit. Conclusions: Postponing IOL implantation some months after simultaneous penetrating keratoplasty and cataract extraction has a negligible effect on the corneal graft endothelium and achieves near postoperative target refraction with significant improvement in UDVA. Key Words: secondary IOL implantation, corneal pathology and cataract, penetrating keratoplasty, simultaneous sequential technique
   
     
 
       

Author Related Publications

  • Ashraf Boraey Mohamed Hassan, "Evaluation the adjunctive use of combined bevacizumab and mitomycinc to trabeculectomy in management of recurrent pediatric glaucoma", Nature Publishing, 2016 More
  • Ashraf Boraey Mohamed Hassan, "Pomegranate protective effect on experimental ischemia/reperfusion retinal injury in rats (histological and biochemical study)", Taylor & Francis, 2017 More
  • Ashraf Boraey Mohamed Hassan, "Pomegranate protective effect on experimental ischemia/reperfusion retinal injury in rats (histological and biochemical study)", Taylor & Francis, 2017 More
  • Ashraf Boraey Mohamed Hassan, "Simultaneous versus sequential photorefractive keratectomy and crosslinking for the management of early keratoconus", مجلة الدلتا الرمدية الاكلينيكية, 2016 More
  • Ashraf Boraey Mohamed Hassan, "Photorefractive keratectomy for residual myopia after myopic laser in situ keratomileusis", مجلة طب العين, 2017 More

Department Related Publications

  • Ahmed Salah Abaas Eldeeb, "دراسة مقارنة استخدام عملية استهلاك العدسة مع شتي قناة شلم وقناةوحقن المادة اللزجة وبين عملية استهلاك العدسة مع قضم الحويجزات لعلاج مرض الزرق", لايوجد, 1900 More
  • Ayman Ahmed Mohamed Elkawas , "TRABECULECTOMY WITH MITOMYCIN 1 /1 /2009 المجلة المجلة", لايوجد, 1900 More
  • Gamal Abdelnaser Mohamed Nagieb Elmoteay, "Management of myopic macular hole with central retinal detachment and posterior staphyloma", لايوجد, 1900 More
  • Gamal Abdelnaser Mohamed Nagieb Elmoteay, "Sequential argon and Nd-YAG laser iridotomies in dark iridis", لايوجد, 1900 More
  • Khaled Goda Amar, "قسم الشبكية بعد حقن عقار الانتروفيرون الفا الداخل الجسم الزجاجي في الارانب دراسة لاستخدام الميكروسكوب الضوئي الالكتروني", لايوجد, 1900 More
Tweet