New potentiometric sensors for creatinine

Faculty Science Year: 2006
Type of Publication: ZU Hosted Pages:
Authors:
Journal: Journal of Pharmaceutical and Biomedical Analysis Netherlands Volume:
Keywords : , potentiometric sensors , creatinine    
Abstract:
Three main types of creatinine potentiometric membrane sensors are described. They are based on the use of dibenzo-30-crown-10 (DB30C10) with potassium tetrakis(p-chlorophenyl)borate type (I), dibenzo-30-crown-10 alone type (II), and potassium tetrakis(p-chlorophenyl)borate alone type (III), incorporating in poly(vinyl chloride) matrix membrane plasticized with either o-nitrophenyl octyl ether or dioctylphthalate. The sensors are used for quantification of creatinine after soaking the membranes in 0.1 M creatinine solution for 2 days. The sensors show almost the same potentiometric response characteristics. Sensor type (I) exhibits Nernstian responses over a concentration range of 5.0 × 10−5 mol l−1–1.0 × 10−2 mol l−1 creatinine with cationic slopes of 59.5 ± 0.1 and 60 ± 0.2 mV decade−1 and detection limits of 1.1 × 10−5 mol l−1 and 8 × 10−6 mol l−1 creatinine, over the pH range of 3.5–6.5 and 3.5–7.0, for o-NPOE and DOP solvent mediators, respectively. Sensor type (II) displays Nernstian responses over a concentration range of 6.0 × 10−5 mol l−1–1.0 × 10−2 mol l−1 creatinine with cationic slopes of 60.0 ± 0.1 and 65.0 ± 0.2 mV decade−1 and detection limits of 1.5 × 10−5 mol l−1 and 1.4 × 10−5 mol l−1 creatinine over the pH range of 2.6–6.2 and 2.5–6.0, for o-NPOE and DOP solvent mediators, respectively. Sensor type (III) shows Nernstian responses over a concentration range of 7.0 × 10−5 mol l−1–1.0 × 10−2 mol l−1 creatinine with cationic slopes of 60 ± 0.1 and 62.0 ± 0.2 mV decade−1 and detection limits of 2.7 × 10−5 mol l−1 and 2.0 × 10−5 mol l−1 creatinine over the pH range of 2.5–6.0, for o-NPOE and DOP solvent mediators, respectively. The response times of the sensors for 10−3 mol l−1 creatinine solution are instantaneous (4–10 s). The sensors show long-term stability with life span of ∼6 months. The sensors are used for determination of serum creatinine of rats (Rattus Norvigicus) with mean R.S.D. of 2.62%, and the results agreed well with the Jaffe kinetic method.
   
     
 
       

Author Related Publications

  • Mohamed Alaa Addeen Fathy Mohamed, "Lead(II) Potentiometric Sensor Based on1,4,8,11-Tetrathiacyclotetradecane Neutral Carrier and LipophilicAdditives", USA, 2008 More
  • Mohamed Alaa Addeen Fathy Mohamed, "Liquid Chromatographic and Potentiometric Methods for Determinations of Clopidogrel", USA, 2008 More
  • Mohamed Alaa Addeen Fathy Mohamed, "Novel Sensors for Batch and Flow Injection Analysis of Histamine Based on Crown Ethers", USA, 2012 More
  • Mohamed Alaa Addeen Fathy Mohamed, "Poly (vinyl chloride) matrix membrane sensors for the quantification of olopatadine and oxeladine in pharmaceutical preparations and human plasma", USA, 2019 More
  • Mohamed Alaa Addeen Fathy Mohamed, "Recognition and Quantification of Some Monoamines Neurotransmitters", USA, 2016 More

Department Related Publications

  • Maher Abdul Rahman Shams al-Din Safty, "Application of chemical reactions on thin-layer chromatography", لايوجد, 1900 More
  • weSam Saber Mohammed Shehab, "Synthesis,Characterization and Evaluation of the Anticancer and Antimicrobial Activities of Some Novel Benzazole and Benzazine Derivatives", Council for Innovative Research, 2013 More
  • Wael Salah AbdelHalim, "Spin quenching of transition metals deposited on MgO insulator and CdO semiconductor density functional calculations", Wiley, 2011 More
  • Wael Salah AbdelHalim, "CO adsorption on Ni, Pd, Cu and Ag deposited on MgO, CaO, SrO and BaO: Density functional calculations", elsevier, 2009 More
  • Walaa Helmy Fahmy Sheweny, "SYNTHESIS, CHARACTERIZATION AND ANTIBACTERIAL ACTIVITY OF NEW Y(ΙΙΙ) AND Zr(ΙV) CIPROFLOXACIN COMPLEXES", LATVIJAS ĶĪMIJAS ŽURNĀLS, 2010 More
Tweet