Onset voltage of negative corona on dielectric-coated electrodes in air

Faculty Engineering Year: 2005
Type of Publication: Article Pages: 3403-3411
Authors: DOI: 10.1088/0022-3727/38/18/013
Journal: JOURNAL OF PHYSICS D-APPLIED PHYSICS IOP PUBLISHING LTD Volume: 38
Research Area: Physics ISSN ISI:000232452900014
Keywords : Onset voltage , negative corona , dielectric-coated electrodes    
Abstract:
This paper describes theoretical and experimental investigations of the effect of an electrode coating on the onset voltage of a corona on negatively stressed electrodes. Dielectric-coated hemispherically-capped rod-to-plane gaps positioned in air are investigated. The onset voltage is calculated based on the self-recurring single electron avalanche developed in the investigated gap. Accurate calculation of the electric field in the vicinity of a coated rod and its correlation to the field values near a bare rod of the same radius are obtained using the charge simulation method. The calculated field values are utilized in evaluating the onset voltage of the corona. Also, laboratory measurements of the onset voltage on bare and coated electrodes are carried out. The effects of varying the field nonuniformity, the coating thickness and its permittivity on the onset voltage values are investigated. The results show that coating the electrodes with a dielectric material is effective in increasing the onset voltage of the corona on its surface. The calculated onset voltage values for coated and bare electrodes agree satisfactorily with those measured experimentally.
   
  Online    
PDF  
       