Zagazig University Digital Repository
Home
Thesis & Publications
All Contents
Publications
Thesis
Graduation Projects
Research Area
Research Area Reports
Search by Research Area
Universities Thesis
ACADEMIC Links
ACADEMIC RESEARCH
Zagazig University Authors
Africa Research Statistics
Google Scholar
Research Gate
Researcher ID
CrossRef
Novel plastic chromium (III)-ion selective electrodes based on different ionophoric species and plasticizing solvent mediators
Faculty
Science
Year:
2006
Type of Publication:
Article
Pages:
299-306
Authors:
GHONEIM, AK, Akl, MA, Abd El-Aziz, MH
DOI:
10.1002/elan.200503407
Journal:
ELECTROANALYSIS WILEY-V C H VERLAG GMBH
Volume:
18
Research Area:
Chemistry; Electrochemistry
ISSN
ISI:000235288400012
Keywords :
crown ethers, chromium(III), ion selective electrodes, calix-[6]arene, alloys, electroplating effluents
Abstract:
Different ionophoric species, viz.: 18-crown-6 (18C6), dibenzo-18-crown-6 (DB18C6) and calix{[}6]arene (CAX), as electroactive materials, with 2-nitrophenyloctylether (2-NPOE), bis(ethylhexyl)sebacate (DOS), dioctyl phthalate (DOP), and didecyl phthalate (DDP) as plasticizing solvent mediators were used to construct Cr3+ selective electrodes in a PVC matrix in the ratio (w/w) PVC: ionophore: plasticizer (60:2:120). Seven electrodes out of the fabricated 12 electrodes, gave best results in terms of working concentration range (1.0 x 10(-5) - 1.0 x 10(-1) M) with a close to Nernstian slope of 18.5 and a Nernstian slope of 20.0 mV/decade of activity. The usable pH range of the sensors is 4.0 - 7.0. The detection limit of the selected electrodes is <= 1.0 x 10(-7) M. The response time of the sensors is 8 - 35 s, depending on the concentration of Cr3+ used. The selectivity coefficient values indicate that the electrodes are highly selective for Cr3+ over a number of other cations except Pb2+ and Na+ (for some electrodes). The electrodes have successfully been used to determine Cr3+ in certified and real alloys and in effluents of electroplating shops with a precision as relative standard deviation (RSD) < 3\%, for each of the proposed Cr3+-ion selective electrodes. The results obtained by the proposed ISEs are in good agreement with the results obtained by direct flame AAS method.
Online
PDF
جامعة المنصورة
جامعة الاسكندرية
جامعة القاهرة
جامعة سوهاج
جامعة الفيوم
جامعة بنها
جامعة دمياط
جامعة بورسعيد
جامعة حلوان
جامعة السويس
شراقوة
جامعة المنيا
جامعة دمنهور
جامعة المنوفية
جامعة أسوان
جامعة جنوب الوادى
جامعة قناة السويس
جامعة عين شمس
جامعة أسيوط
جامعة كفر الشيخ
جامعة السادات
جامعة طنطا
جامعة بنى سويف