Zagazig University Digital Repository
Home
Thesis & Publications
All Contents
Publications
Thesis
Graduation Projects
Research Area
Research Area Reports
Search by Research Area
Universities Thesis
ACADEMIC Links
ACADEMIC RESEARCH
Zagazig University Authors
Africa Research Statistics
Google Scholar
Research Gate
Researcher ID
CrossRef
Application of a validated, stability-indicating LC method to stress degradation studies of ramipril and Moexipril.HCl
Faculty
Pharmacy
Year:
2008
Type of Publication:
Article
Pages:
567-573
Authors:
Elgawish, Mohamed S, Mostafa, Samia M, Elshanawane, Abdalla A
DOI:
10.1365/s10337-008-0544-3
Journal:
CHROMATOGRAPHIA VIEWEG
Volume:
67
Research Area:
Biochemistry \& Molecular Biology; Chemistry
ISSN
ISI:000254750200009
Keywords :
column liquid chromatography, ramipril, moexipril.HCl, stability-indicating
Abstract:
A stability-indicating reversed-phase liquid chromatographic (RPLC) method has been established for analysis of ramipril ( RAM) and moexipril hydrochloride (MOEX.HCl) in the presence of the degradation products generated in studies of forced decomposition. The drug substances were subjected to stress by hydrolysis (0.1 M NaOH and 0.1 M HCl), oxidation (30\% H2O2), photolysis (254 nm), and thermal treatment ( 80 degrees C). The drugs were degraded under basic and acidic conditions and by thermal treatment but were stable under other stress conditions investigated. Successful separation of the drugs from the degradation products was achieved on a cyanopropyl column with 40: 60 (v/v) aqueous 0.01 M ammonium acetate buffer (pH 6)-methanol as mobile phase at a flow rate of 1 mL min(-1). Detection was by UV absorption at 210 nm. Response was a linear function of concentration over the range 5-50 mu g mL(-1) ( r > 0.9995), with limits of detection and quantitation (LOD and LOQ) of 0.04 and 0.09 mu g mL(-1), respectively, for RAM and 0.014 and 0.32 mu g mL(-1), respectively, for moexipril. The method was validated for specificity, selectivity, solution stability, accuracy, and precision. Statistical analysis proved the method enabled reproducible and selective quantification of RAM and MOEX as the bulk drug and in pharmaceutical preparations. Because the method effectively separates the drugs from their degradation products, it can be used as stability-indicating.
Online
PDF
جامعة المنصورة
جامعة الاسكندرية
جامعة القاهرة
جامعة سوهاج
جامعة الفيوم
جامعة بنها
جامعة دمياط
جامعة بورسعيد
جامعة حلوان
جامعة السويس
شراقوة
جامعة المنيا
جامعة دمنهور
جامعة المنوفية
جامعة أسوان
جامعة جنوب الوادى
جامعة قناة السويس
جامعة عين شمس
جامعة أسيوط
جامعة كفر الشيخ
جامعة السادات
جامعة طنطا
جامعة بنى سويف