Heat transfer characteristics of rotating triangular thermosyphon

Faculty Science Year: 2012
Type of Publication: Article Pages: 1539-1548
Authors: DOI: 10.1007/s00231-012-0995-9
Journal: HEAT AND MASS TRANSFER SPRINGER Volume: 48
Research Area: Thermodynamics; Mechanics ISSN ISI:000307963000006
Keywords : Heat transfer characteristics , rotating triangular thermosyphon    
Abstract:
An experimental investigation is carried out to study heat transfer characteristics of a rotating triangular thermosyphon, using R-134a refrigerant as the working fluid. The tested thermosyphon is an equilateral triangular tube made from copper material of 11 mm triangular length, 2 mm thickness, and a total length of 1,500 mm. The length of the evaporator section is 600 mm, adiabatic section is 300 mm, and condenser section is 600 mm. The effects of the rotational speed, filling ratio, and the evaporator heat flux on each of the evaporator heat transfer coefficient, h(e), condenser heat transfer coefficient, h(c), and the overall effective thermal conductance, C-t are studied. Experiments are performed with a vertical position of thermosyphon within heat flux ranges from 11 to 23 W/m(2) for the three selected filling ratios of 10, 30 and 50 \% of the evaporator section volume. The results indicated that the maximum values of the tested heat transfer parameters of the rotational equilateral triangular thermosyphon are obtained at the filling ratio of 30 \%. Also, it is found that the heat transfer coefficient of the condensation is increased with increasing the rotational speed. The tested heat transfer parameters of the thermosyphon are correlated as a function of the evaporator heat flux and angular velocity.
   